Fit Head-Flow Rate Data to a Pump Curve - Maple Help
For the best experience, we recommend viewing online help using Google Chrome or Microsoft Edge.
Our website is currently undergoing maintenance, which may result in occasional errors while browsing. We apologize for any inconvenience this may cause and are working swiftly to restore full functionality. Thank you for your patience.

Online Help

All Products    Maple    MapleSim


Home : Support : Online Help : Applications and Example Worksheets : Science and Engineering : Fit Head-Flow Rate Data to a Pump Curve

Fit Head-Flow Rate Data to a Pump Curve

Introduction

This application will fit experimental head-flow rate data to a polynomial pump curve.

withCurveFitting: withplots:

Head-Flow Rate Data

flowData415614.5813.751012.701211.25149.5:

p1plotflowData,style=point,symbol=solidcircle,symbolsize=20,labels=Flow Rate (cfm),Head (ft),labeldirections=horizontal,vertical

Curve Fitting

Head Curve

fabQ2:

bestFitCurveLeastSquaresflowData,Q,curve=abQ2

bestFitCurve15.62389735364880.0306535685645549Q2

(3.1)

p2plotbestFitCurve,Q=4..14:

displayp1,p2,axesfont=Arial,labelfont=Arial